Rat IgG Quantification Kit
ELISA kit for the quantification of rat IgG in cell culture supernatants and rat ascites fluid. Ready-to-use, color-coded reagents with seven standards included. Assay time: approximately 30 minutes. Detection range: 16 to 2,000 ng/mL. Available in 1-, 5-, or 10-plate formats with 96 wells per plate. For research use only.
Description
The Rat Immunoglobulin Quantification Kit is designed for the quantitative determination of rat IgG in cell culture supernatants and rat ascites fluid. It detects all rat IgG subclasses. The one-step sandwich ELISA method combines sample and detection antibody incubation, enabling analysis in approximately 30 minutes after the reagents have been brought to room temperature for 30 minutes.
The microwells are pre-coated with polyclonal anti-rat IgG (H+L) antibodies. Detection is based on an HRP-conjugated anti-rat IgG (H+L) antibody, followed by TMB colorimetric development. After stopping the reaction, absorbance is measured at 450 nm and 620 nm. The concentration is determined from the standard curve, with a four-parameter curve fit recommended.
Ready-to-use reagents and color-coded solutions facilitate pipetting. Seven standards cover concentrations from 0 to 2,000 ng/mL. The detection range is 16 to 2,000 ng/mL, with a detection limit of 5 ng/mL. No cross-reactivity with human or bovine IgG was observed by ELISA, while cross-reactivity with mouse IgG is below 8%.
Store the kit at 2–8°C. Do not freeze. After opening, use the reagents within two months.
Additional information
| Product Type | IgG Quantification Kit |
|---|---|
| Method | One-step ELISA |
| Target Species | Rat |
| Application | Quantitative Determination of Rat IgG |
| Compatible Samples | Cell culture supernatants, Rat ascites fluid |
| Principle | ELISA sandwich quantitatif |
| Detection Range | 16 to 2 000 ng/ml |
| Detection Limit | 5 ng/ml |
| Standard Concentrations | 0, 16, 125, 250, 500, 1 000, 2 000 ng/ml |
| Stated Duration | Approximately 30 minutes, excluding reagent equilibration to room temperature |
| Capture Antibody | Pre-coated polyclonal anti-rat IgG (H+L) antibodies |
| Substrate | TMB |
| Absorbance Reading | 450 nm and 620 nm; analysis of A450 − A620 |
| Volume per Well | 20 µL of diluted sample or standard |
| Recommended Dilutions | Supernatant: 1:100; Miniperm® / CELLine®: 1:1,000; ascites fluid: 1:5,000 |
| Cross-reactivity | No cross-reactivity observed with human or bovine IgG; < 8% with mouse IgG |
| Storage | 2–8°C; do not freeze |
| Use After Opening | Within 2 months; avoid contamination |
| Intended Use | For Research Use Only |
| Format | 1 × 96 wells (RDB-3259-1), 5 × 96 wells (RDB-3259-5), 10 × 96 wells (RDB-3259-10) |
| 8-well strips | 12 (RDB-3259-1), 60 (RDB-3259-5), 120 (RDB-3259-10) |
| Stated Capacity | 89 samples (RDB-3259-1), 450 samples (RDB-3259-5), 900 samples (RDB-3259-10) |
| Sample Diluent | 30 ml (RDB-3259-1), 150 (RDB-3259-5), 500 ml (RDB-3259-10) |
| Detection Antibody | 12 ml (RDB-3259-1), 60 (RDB-3259-5), 120 ml (RDB-3259-10) |
| TMB | 12 ml (RDB-3259-1), 60 (RDB-3259-5), 120 ml (RDB-3259-10) |
| Stop Solution | 12 ml (RDB-3259-1), 60 ml (RDB-3259-5), 120 ml (RDB-3259-10) |